9
SPECIFICATIONS
11
Specifications
1. Continuous output power 200w
2. Surge rating (0.1second) 400w
3. Peak efficiency (12V—1/2 load) 90%
4. Efficiency (full load, 12V) >78%
5. No load current draw < 0.45 A (12.6V)
6. Output waveform (resistive load) Perfect modified
sine wave
7. Output frequency 60Hz ± 2Hz
8. Output voltage 115V +/- 10%
9. USB output 5V
10. Input voltage 12.8 - 13.2 VDC
12. Shutdown voltage (unload) 10.0V ±0.3V
13. Operating temperature range -10° C + 40° C
14. Storage temperature range -40° C to 85° C
15. Protection Overload, short-circuit, Overtemp
16. Reverse polarity, under/over voltage
NOTES: All protection is automatically recovered. To protect the
battery, if the unit needs to be restarted after low voltage protection,
the voltage of DC input should be above 12V.