SPECIAL PROGRAMMING SECTION:
S
argent KP Lock factory Master
Code is 1234”. Entering 1234*
unlocks and allows lever to retract
latchbolt.
All of the following procedures start
with 99# to enter programming mode.
Change Master Code: 1234* (Yellow LED
Begins to Blink Slowly). This example uses
the Factory Default Master Code
50# 1# 01# New Master Code*
(Yellow LED Blinks Quickly) .
New Master Code* (Yellow LED
Blinks Slowly) *(Yellow LED Goes Out)
Enter Emergency Code: (Unlock Duration
Factory Set at 10 Sec)
Master Code* (Yellow LED begins to
blink slowly)
50# 1# 02# Emergency Code* (Yellow
LED blinks quickly)
Emergency Code* (Yellow LED Blinks
Slowly) * (Yellow LED goes out)
Enter Supervisory Code: Master Code*
(Yellow LED begins to blink slowly)
50# 1# 03# Super visory Code*
(Yellow LED blinks quickly)
Supervisory Code* (Yellow LED Blinks
Slowly) *(Yellow LED goes out)
Enter User Code: Supervisory or Master
Code* (Yellow LED begins to blink slowly)
50# 1# User Number (04-97)# User
Code* (Yellow LED blinks quickly)
User Code* (Yellow LED blinks
slowly)* (Yellow LED goes out)
Enter Passage (Maintained Mode) Code:
Supervisory or Master Code* (Yellow LED
Begins to blink slowly)
50# 2# User Number (04-97)# User
Code* (Yellow LED blinks quickly)
User Code* (Yellow LED Blinks
Slowly)* (Yellow LED goes out)
Enter One-Time User Code: Supervisory or
Master Code* (Yellow LED begins to blink
slowly)
50# 3# User Number# User Code*
(Yellow LED blinks quickly)
User Code* (Yellow LED Blinks
Slowly) * (Yellow LED goes out)
Clear Entire Memory: Master Code* (Yellow
LED Begins to Blink Slowly)
46# 00000# 00000# (Yellow LED
Continues to Blink Slowly)
* (Yellow LED Blinks Quickly)
* (No Beep on Depression and Yellow
LED Goes Out)
PAUSE, Yellow LED Begins to Blink
Again
* (Yellow LED Goes Out)
Note: This deletes ALL codes, includ-
ing Master, Emergency and Supervisory.
Master Code is set back to 1234, Door
Number to 0001 and Unlock time 5 Sec.
If the Master Code is unknown, Factory
Assistance will be required to clear the
memory. Call 1-800-810-WIRE
Categories Sargent KP
ANSI/BHMA A156.2 Grade 1
Lock Cylinder Grade
UL/ULC fire rating 3 hour ‘Alabel doors
Clutched Lever n/a
Available as Cylindrical, Mortise or Exit Device Trim
Lever Handing Some non-Handed
Field Reversible? Yes
Key Override Yes
Optional No
Keypad Layout Telephone-Style 12-button
Button Construction ultraviolet stable textured material
Code Hierarchy Master, Emergency, Supervisor, Users
Master Code # Digits 2-6,
Notes: Can repeat numbers or start
with “0”.
Yellow indicates programming
Factory Default Master 1-2-3-4
Notes: Only Master code deletes Users.
Sub-master Codes # 1 Emergency, 1 Supervisor
Number Of Digits 2-6
User Codes no. up to 96
# of digits 1-6
Notes: Can be different lengths, Can repeat numbers. Two User Codes have 10 sec open
time (98, 99)
Single use code Up to 96
Successful Entry Green LED, pasage mode, flashing green LED
User code groups n/a
Notes: When Passage Mode is activated, same User Code must be used to re-lock Lock.
Levels of access Code required, passage
Programming Capabilities Master Code: all, Emergency Code :10 second
unlock time
Supervisor Code limited, No Users deleted by Supervisor Code
Codes on hold Temporary Lockout
Anti-Tamper 3 wrong codes in succession disables all codes
for 10 seconds
Battery Life Minimum 40,000 cycles
Low Batteries Warning Four chirps after each code entry
Batteries Four “C”
Battery Location Inside of Battery cover, secured with 8-32 hex
head security screw
Battery Information Warnings Non-volatile solid state memory
Notes: If a mistake is made during any programming procedure, depress the “*”
several times until the yellow LED goes out. If no keystroke is made in a 30 seconds, the
unfinished programming up to that point will default and you will have to start over. If
after the last “*” is depressed, the yellow LED does not go out, depress “*” once more.
SARGENT KP LOCK
54 — LOCKSMITH LEDGER [11/10] www.locksmithledger.com